Segmental Retaining Wall

ConTec WR-650

DESCRIPTION

ConTec WR-650 integral water-repellant is a highly active powder additive designed to reduce permeability and efflorescence in concrete manufactured products. When used properly this unique formulation chemically reacts and bonds utilizing the alkali properties of concrete to provide long lasting performance.

APPLICATION

ConTec WR-650 can be used in a variety of
cementitious dry mix applications where the use of conventional water repellants is not feasible or desired. When used in both mortar and masonry units WR-650 provides permanent protection from water infiltration throughout masonry walls.

PACKAGING

ConTec WR-650 is available in bulk Bags weighing 2204 lbs (1000 kg) or packaged in 22 lb (10 kg) bags stacked 60 bags per pallet. An ICT representative will determine the proper dispensing system to match your operation.

TYPICAL PROPERTIES

Form…….…… ….. ……………………..Powder
Color / Odor………… …..…. White / Slight
Bulk Density …………………. …….400 kg/m3
% Volatile matter (NVM(1)) ………… …… 0.0
VOCs (lbs/gallon) ………………………..None

FEATURES / BENEFITS

● Superior water repellence.
● Improved soil release properties.
● Compatible with other additives.
● Improves durability and freeze/thaw resistance.
● Greatly reduces efflorescence.
● Good alkaline stability.
● High activity lowers addition rates.
● Inhibits water-wicking.

HANDLING / STORAGE

ConTec WR-650 must be stored in a cool, dry, well–ventilated area. When stored properly, WR-650 has a shelf life of 6 to 12 months. Although WR-650 is a low dust formulation always avoid excessive dust formation when handling.

ADDITION RATES

Always consult your ICT technical representative for recommendations for your application.

ConTec EC-166

DESCRIPTION

ConTec EC-166 is a integral water repellant admixture used in low slump concrete units such as architectural block, paving stones, SRW units, or masonry mortar. ConTec EC-166 contains a unique blend of efflorescence control agents and polycarboxylate cement and pigment dispersion aids. ConTec EC-166 contains new and improved primary efflorescence control and enhances the color and appeal of all types of concrete products. When used in both mortar and masonry units EC-166 reduces water infiltration through masonry walls.

APPLICATION

Use ConTec EC-166 in all types of manufactured concrete in which the reduction of efflorescence and water permeability is desirable.

PACKAGING

ConTec EC-166 is available in bulk quantities or packaged in 55 gallon (208 L) drums weighing 480 lbs (218 kg) and 265 gallon (1003 L) totes weighing 2400 lbs (1089 kg).

TYPICAL PROPERTIES

Specific Gravity at 77F……..…….. 1.02
Viscosity at 77F, cps …………….  < 300
Weight per gallon ……… …….….. 8.4
% Volatile matter (NVM(1)) …… ~ 60

FEATURES / BENEFITS

●   Increases hydrophobic properties and lowers absorption rates.
●  Contains high levels of polycarboxylate dispersants for strength.
●   Impedes the formation of primary and secondary efflorescence.
●   Increases product freeze-thaw durability with its unique densifying properties.
●   Aids color development and can shorten production cycles.
●   Reduces mechanical abrasion in equipment

HANDLING / STORAGE 

ConTec EC-166 should be stored at temperatures above 40°F (4.5°C)  Care should be taken to prevent this product from freezing. Should EC-166 become frozen the resulting material will be unusable.

ADDITION RATES

We recommend the following range of dosage: 8 to 16 fluid ounces per hundred weight of cement for concrete paving stones and concrete roof tile. For SRW units and other architectural block higher dosage rates may be recommended. These dosage rates are estimated, your actual rate should be determined by testing. We recommend the assistance of an ICT technical representative to help you determine the proper dosage rate and order of addition for your particular process. Order of addition procedures can vary per facility. Never mix EC-166 with other admixtures before application.

MSDS

ConTec EC-135

DESCRIPTION

ConTec EC-135 is a integral water repellant admixture used in low slump concrete units such as architectural block, paving stones, SRW units, or masonry mortar. When used properly this unique formulation chemically reacts with concrete to prevent water penetration and control efflorescence. ConTec EC-135 contains new and improved primary efflorescence control and enhances the color and appeal of all types of concrete products. When used in both mortar and masonry units EC-135 reduces water infiltration through masonry walls.

APPLICATION

Use ConTec EC-135 in all types of manufactured concrete in which the reduction of efflorescence and water permeability is desirable.

PACKAGING

ConTec EC-135 is available in bulk quantities or packaged in 50 gallon (189 L) drums weighing 440 lbs (200 kg) and 265 gallon (1003 L) totes weighing 2400 lbs (1089 kg).

TYPICAL PROPERTIES

Specific Gravity at 77F…….… ….. 1.008
Viscosity at 77F, cps …………..….  < 200
Weight per gallon …………… …….….. 8.4
% Volatile matter (NVM(1))… …… ~ 60

FEATURES / BENEFITS

●   Increases hydrophobic properties and  lowers absorption rates.
●   Impedes the formation of primary and secondary efflorescence.
●   Increases product durability with its unique densifying properties.
●   Aids color development and can shorten production cycles.
●   Reduces mechanical abrasion in equipment

HANDLING / STORAGE

ConTec EC-135 should be stored at temperatures above 40°F (4.5°C)  Care should be taken to prevent this product from freezing. Should EC-135 become frozen the resulting material will be unusable.

ADDITION RATES

We recommend the following range of dosage: 8 to 16 fluid ounces per hundred weight of cement for concrete paving stones and concrete roof tile. For SRW units and other architectural block higher dosage rates may be recommended. These dosage rates are estimated, your actual rate should be determined by testing. We recommend the assistance of an ICT technical representative to help you determine the proper dosage rate and order of addition for your particular process. Order of addition procedures can vary per facility. Never mix EC-135 with other admixtures before application.